THE GLOBAL EDITION 01
English
← Isle of Man country profileSOURCED ENGINEERING PROFILE

Pulrose CCGT power station

Pulrose's 88 MW CCGT block: sourced alternator ratings, turbine types, 33 kV switchhouse and 2024/25 generation, distinct from diesel units and live output.

Locate this plant on the map

Reported facts and record scope

Inventory facts below come from Manx Utilities — Pulrose CCGT. Unknown ownership remains separate from the operator.

Country / territory
Isle of Man
Technology
Combined-cycle gas turbine
Reported installed / rated capacity
88 MW
Owner in inventory
Not reported
Operator in inventory
Manx Utilities
Commissioning year
2003
Source status
Operator-described station; current availability unverified
Upstream snapshot date
Not specified by the source

Sourced engineering details

The combined-cycle gas block at Pulrose only. Adjacent diesel equipment and wider-site totals are excluded.

Installed or rated capacity (MW), generator apparent power (MVA) and annual electricity generation (MWh/GWh) describe different quantities. None is live output. No live telemetry is connected to this profile.

Generator / unit ratings
Gas alternators: 2 × 41.25 MVA; steam alternator: 31.625 MVAReported source record

Source period: Historical Manx Electricity Authority technical brochure; publication date not stated

The brochure identifies ABB AMS-1250-LK gas alternators and an LDW S5E11 20 M66-42P steam alternator. It lists two 32 MW gas-turbine outputs, 23 MW steam-turbine generator electrical output, 87 MW gross, 3 MW auxiliary demand and 84 MW net. The operator overview separately reports 88 MW for the block; the difference is not reconciled by the checked sources. MVA is apparent power, not MW or present output.

Grid connection voltage
33 kV switchhouse reported; precise connection point not confirmedReported source record

Source period: Historical technical brochure; publication date not stated

This is the published switchhouse voltage. It must not be relabelled as generator-terminal voltage or a verified current point-of-connection specification.

Turbine type
2 × GE LM2500+ aero-derivative gas turbines + 1 × MAN steam turbineReported source record

Source period: Historical technical brochure; operator overview describes the block built in 2003

The brochure identifies the steam turbine as MAN DK080/250RZ1. Equipment descriptions concern the documented configuration; no claim is made about current availability, overhaul status or uprating.

Annual electricity generation
417 GWh in the year ended 31 March 2025Reported source record

Source period: Financial year 2024/25; annual report published as Tynwald GD 2026/0048

The operator reports 417 million kWh specifically from Pulrose's combined-cycle plant. The report does not identify the gross/net metering boundary in that paragraph. Diesel generation is reported separately and is not added here.

Operating principle
Gas turbines generate electricity; exhaust heat raises steam for a second generating cycleReported source record

Source period: Historical technical brochure; publication date not stated

Heat-recovery steam generators recover gas-turbine exhaust heat for the steam turbine. The two diagram paths show energy conversions, not alternators electrically connected in series or an operating procedure.

Illustrative energy paths

Teaching illustration — not an as-built plant diagram. This editorial diagram explains the sourced operating principle above. It is not to scale and does not show actual wiring, equipment locations, protection settings or an approved installation design.

Gas-turbine electricity path

  1. Air + natural gas
  2. Gas turbines
  3. Gas alternators
  4. Electrical network

Recovered-heat electricity path

  1. Gas-turbine exhaust heat
  2. Heat recovery → steam
  3. Steam turbine + alternator
  4. Electrical network

The paths show the combined-cycle principle, not site piping, busbars, switchgear or a single-line diagram. Diesel generation is omitted from this CCGT illustration.

Explore the generic technology model and explanation. That model is illustrative, not a reconstruction of this plant.

The gas block and the wider site

Manx Utilities describes an 88 MW combined-cycle gas-turbine block built in 2003. The adjacent diesel station is a separate installation sharing the site and control room. This atlas record covers the CCGT block only, so its 88 MW must not be compared directly with the operator's nearly 135 MW figure for the wider Pulrose site. Manx Utilities: power stations.

Technology and record limits

The operator describes aero-derivative gas turbines and a 7 July 2003 opening. Combined-cycle technology couples a gas-turbine cycle with heat recovery and a steam cycle. Owner identity is not separately reported in this inventory; the operator field must not be silently substituted for ownership. Manx Utilities: Pulrose CCGT.

Location and interpretation limits

NESO grid reference SC 367 756 has 100-metre precision. This record describes the 88 MW CCGT block; adjacent diesel units are excluded. Supported by National Energy SO Open Data.

A representative coordinate is not a surveyed boundary or a grid connection diagram. Rated MW is not real-time output. Historical annual generation is separately dated; this profile does not verify current dispatch or availability.

Editorial references checked on . This review date does not refresh the compiled inventory or establish a new source publication date.

Inventory references

Explore the context